Resources
Back

The address goes to the US Census lookup to find its town or county. We don't save it.

Typical rules to help you plan. Setbacks can differ by zoning district, plat, PD/PUD, HOA, easements and variances. Always confirm with the city or county before you build. ScreenCAD isn't responsible for decisions made from this page.

City of Tampa

City in Hillsborough County

Through lot

Step 1: Check the zoning district

Open the zoning map

Setbacks

Side setback

Pool screen enclosure

5'

From the side line, for a wall up to 15' tall. Over 15': 6'; at 25': 7' (1' more for every 10').

Details & code

Sec. 27-290.5

Source · Last checked: October 26, 2026 · Confirmed

Screen room (screen roof, no pool)

5'

From the side line, for a wall up to 15' tall. Over 15': 6'; at 25': 7' (1' more for every 10').

Details & code

Sec. 27-290.5

Source · Last checked: October 26, 2026 · Confirmed

Solid-roof porch

  • Zoning district RS-50, RS-60, RS-75:7'
    What's this?

    Your zoning district is a code on the city or county zoning map (e.g. RS-50 = single-family residential). Find yours with 'Open the zoning map' above.

  • Other districts:Ask zoning

A solid-roof porch takes the house's side setback.

Details & code

Sec. 27-156, Table 4-2

Source · Last checked: October 26, 2026 · Official record

Solid-roof screen room

  • Zoning district RS-50, RS-60, RS-75:7'
  • Other districts:Ask zoning

A solid-roof porch takes the house's side setback.

Details & code

Sec. 27-156, Table 4-2

Source · Last checked: October 26, 2026 · Official record

Street side setback

Pool screen enclosure

  • Zoning district RS-50, RS-60:7'
  • Zoning district RS-75:15'
  • Other districts:Ask zoning

Street side of a corner lot: the district's setback.

Details & code

Zoning district RS-50, RS-60

Sec. 27-156, Table 4-2

Source · Last checked: October 26, 2026 · Official record

Zoning district RS-75

Sec. 27-156, Table 4-2

Source · Last checked: October 26, 2026 · Official record

Screen room (screen roof, no pool)

  • Zoning district RS-50, RS-60:7'
  • Zoning district RS-75:15'
  • Other districts:Ask zoning

Street side of a corner lot: the district's setback.

Details & code

Zoning district RS-50, RS-60

Sec. 27-156, Table 4-2

Source · Last checked: October 26, 2026 · Official record

Zoning district RS-75

Sec. 27-156, Table 4-2

Source · Last checked: October 26, 2026 · Official record

Solid-roof porch

  • Zoning district RS-50, RS-60:7'
  • Zoning district RS-75:15'
  • Other districts:Ask zoning

Street side of a corner lot: the district's setback.

Details & code

Zoning district RS-50, RS-60

Sec. 27-156, Table 4-2

Source · Last checked: October 26, 2026 · Official record

Zoning district RS-75

Sec. 27-156, Table 4-2

Source · Last checked: October 26, 2026 · Official record

Solid-roof screen room

  • Zoning district RS-50, RS-60:7'
  • Zoning district RS-75:15'
  • Other districts:Ask zoning

Street side of a corner lot: the district's setback.

Details & code

Zoning district RS-50, RS-60

Sec. 27-156, Table 4-2

Source · Last checked: October 26, 2026 · Official record

Zoning district RS-75

Sec. 27-156, Table 4-2

Source · Last checked: October 26, 2026 · Official record

Rear setback

Pool screen enclosure

5'

From the rear line, for a wall up to 15' tall. Over 15': 1' more for every foot or part of a foot (15'-1" needs 6', 16'-1" needs 7').

Details & code

Reviewers read the over-15' rule differently: Leo confirmed this reading with a Tampa zoning reviewer. Get it in writing for your job (TampaZoning@tampagov.net).

Sec. 27-290.5

Source · Last checked: October 26, 2026 · Confirmed

Screen room (screen roof, no pool)

5'

From the rear line, for a wall up to 15' tall. Over 15': 1' more for every foot or part of a foot (15'-1" needs 6', 16'-1" needs 7').

Details & code

Reviewers read the over-15' rule differently: Leo confirmed this reading with a Tampa zoning reviewer. Get it in writing for your job (TampaZoning@tampagov.net).

Sec. 27-290.5

Source · Last checked: October 26, 2026 · Confirmed

Solid-roof porch

  • Zoning district RS-50, RS-60, RS-75:20'
  • Other districts:Ask zoning

A solid-roof porch takes the house's rear setback.

Details & code

Sec. 27-156, Table 4-2

Source · Last checked: October 26, 2026 · Official record

Solid-roof screen room

  • Zoning district RS-50, RS-60, RS-75:20'
  • Other districts:Ask zoning

A solid-roof porch takes the house's rear setback.

Details & code

Sec. 27-156, Table 4-2

Source · Last checked: October 26, 2026 · Official record

Height

Height limit

Pool screen enclosure

35'

The tallest a screen enclosure can be. Over 15', the side and rear setbacks grow (see Setbacks).

Details & code

Sec. 27-290.5

Source · Last checked: October 26, 2026 · Confirmed

Screen room (screen roof, no pool)

35'

The tallest a screen enclosure can be. Over 15', the side and rear setbacks grow (see Setbacks).

Details & code

Sec. 27-290.5

Source · Last checked: October 26, 2026 · Confirmed

Solid-roof porch, Solid-roof screen room

Trees

Trees

  • 5–23" trunk:10'Protected trees: keep the work this far from the edge of the trunk. Show trees within 20' of the work on the site plan.
  • 24–31" trunk:15'Specimen trees: keep the work this far from the edge of the trunk.
  • 32" trunk and up:20'Grand trees: keep the work this far from the edge of the trunk.
Details & code

5–23" trunk

Sec. 27-284

Source · Last checked: November 3, 2026 · Official record

24–31" trunk

Sec. 27-284

Source · Last checked: November 3, 2026 · Official record

32" trunk and up

Sec. 27-284

Source · Last checked: November 3, 2026 · Official record

Watch out for

  • Other zoning districts and planned developments (PDs) have their own numbers.

  • A change to the house setback table is pending and not online yet: check solid-roof porch setbacks with zoning.

  • Waterfront: a pool within 36" of grade is 5' from the rear line, mean high water or the seawall, whichever is stricter. Accessory structures: 15' from the Hillsborough River seawall or line. Wetland buffer: 15' minimum, 25' average.

    Details & code

    Source · Last checked: October 26, 2026

  • New concrete (footers or a slab) needs termite treatment and a Certificate of Compliance, uploaded to the permit before the final.

  • Inspections: pre-construction, slab and final.

    Details & code

    Source · Last checked: November 2, 2026

Field notes

3'

A detached porch or other accessory building: 3' side, 3' rear, 60' from the front line, max 15' tall.

Details & code

Corner lot street side 7' (15' in RS-75, RS-100, RS-150). Gross area under 15% of the minimum lot size, or it takes house setbacks. Keep it 5' from the house (10' in RS-75, RS-100, RS-150), eave to eave. A covered walkway open on 2 or more sides may connect it. An attached solid-roof porch is a covered patio and takes house setbacks (Sec. 27-290.5(1)c).

Sec. 27-290(1)a

Source · Last checked: October 26, 2026 · Confirmed

A detached building connected to the house by a screen enclosure stays accessory if the separation is kept. Ask zoning how they apply it to your job.

Details & code

Only an enclosed passageway or a room addition makes everything meet house setbacks.

Sec. 27-290.3(3), 27-290(1)a.3

Source · Last checked: October 26, 2026 · Confirmed

Permits

How to submit

Permit portalOpen
Portal typeAccela
Paper or in personAsk
Same-day walk-through reviewNo
Typical review timeAsk

Source · Last checked: November 2, 2026

What to submit

  • Apply as Residential Miscellaneous › Building › "Aluminum Screen Room/Pool Cage/Porch" in Accela

    Source · Last checked: October 26, 2026

  • Site plan (no signature needed): property lines, elevations, the enclosure's location and size, other structures, power lines, trees within 20', easements

    Source · Last checked: October 26, 2026

  • Signed and sealed plans: no password-protected files, stamps flattened

    Source · Last checked: October 26, 2026

4 more
  • Sealed survey (NAVD 88), only over about 1,000 sq ftIf it applies

    Source · Last checked: October 26, 2026

  • Contractor's Letter of Authorization, for an agentIf it appliesNotarized

    Source · Last checked: October 26, 2026

  • Notice of CommencementIf it appliesNotarized

    Source · Last checked: October 26, 2026

  • Owner-builder form (not notarized)If it applies

    Source · Last checked: October 26, 2026

Contacts

Building department813-274-3100, option 1
Building emailCSDHelp@tampagov.net
Permit portalOpen
Building pageOpen
Zoning mapOpen
Written zoning answerFree: book a Plan Review Consultation (virtual or in person) at Q-Up Tampa. In writing: a Certification Letter, $55.50, through Accela. · Open

Source · Last checked: November 2, 2026

Parcel lookupOpen
Florida rules that apply everywhere

Need the layout for this job?

Order your layout